This is a microwave sensor switches controlled LED lights,the microwave sensor was built into the light ,it has 72pcs high brightness LEDs inside ,with total power of 18 watts. When light on, the luminous flux will be more than 900 lm, equivalent to that of 60 watt incandescent lamp(≈400lm) and the life exceeds 50,000 hours. We adopt this sensitive advanced sensor switchs in lighting control, enabling the light to turn on automatically when one comes , automatically turn off when one goes out In addition to the widely usage in the aisle stairs ,living room and bedrooms , it also can be installed in the bathroom.
In order to be convenient for the fixing, adjusting and production,after being charged with electricity for the first time, the time delay of the induction will be 3 seconds for the first three times, after then, the sensor will go into normal operating mode ( the exact time delay value should take the potentiometer as the standard).
Specification
Power source: 100-250V/AC
Power frequency: 50/60Hz
Rated load: 18W Max.
PF:0.92--0.95
HF system: 5.8GHz CW electric wave,
ISM wave band
Time setting: 8sec to 12min (adjustable)
Detection range: 1-8m (radii.)(adjustable)
Light-control: 10-1000LUX(adjustable)
Standby power: <0.5W
Detection angle: 360°
Luminous flux: 950lm--1050lm
Installation height: 2.5-4.5m
(ceiling mount)
Working temperature: -10°C~+55°C
Lamp part
LED quanlity: 0.3Wx72PCS
LED specifications: 2835
Fault and the solution
Fault | Failure cause | Solution |
The load fails to work. | Light-illumination is set incorrectly. | Adjust the setting of the load. |
The load is broken. | Change the load. | |
The power is off. | Turn the power on. | |
The load works all the time. | There is a continuous signal in the region of the detection. | Check the settings of the detection area. |
The load works when there is no motion signal detected. | The lamp isn't installed well so that sensor fails to detect reliable signals. | Re-adjust the installation place. |
Moving signal is detected by the sensor (movement behind the wall, the movement of small objects, etc.) | Check the settings of the detection area. | |
The load fails to work when there is motion signal detected. | The motion speed is too fast or the defined detection area is too small. | Check the settings of the detection area. |
1.The LEDS in serial can function when all the seals installed in place.
2.Please don’t remove or connect with other lamp when powered on.
3.When the LEDS in serial are damaged ,you need experienced technician to repair using the same rating LEDS.
4.In order to convenient installation and production,after first put on electrict,first three times detection delay will be 3 seconds,then enter to normal mode(the specific delay time subject to potentiometer)
●Please confirm with profession installation.
●Please cut off power supply before installation and removal operations.
●Make sure that you have cut off the power for safety purposes.
●Improper operation caused losses, the manufacturer does not undertake any responsibility.