PDLUX PD-IN2006
When use LED IP44 Waterproof Microwave Induction Lamp, please adjust the sensitivity to an appropriate position you need, please do not adjust the sensitivity to maximum, to avoid the product does not work normally caused by wrong motion.Because the sensitivity is too high easily detect the wrong motion by wind blowing leaves & curtains, small animals, and the wrong motion by interference of power grid & electrical equipment. All those lead the product does not work normally !
Microwave Sensor Lamp PD-IN2006 Instruction
|
PRODUCT INFORMATION
This product appearance is concise, easy, use range (sitting room, bedroom, study, corridor, etc), function of advanced internal microwave sensors try products humanized control.
The microwave sensors is according to the microwave doppler effect <the basic principle of radar> , it can be widely used in as automatic control switch, the security system, and automatic video control system of ATM, as well as other automatic induction control area. The detection way has the below advantages compared with other as follows: 1. Non-contact detection, 2. Suitable for bad environment, immune to temperature, humidity, noise, air, dust, light…3.RF interference ability, 4.Transmission power only 0.3 mW, It will not harm the human body. Simple installation+ easy wiring. We use appropriative micro processing integrator, not only for high sensitivity and wide range of detection, and on very reliable work, error rate is extremely low, It can stable working on the temperature range: - 15 ~ + 70 degrees.
|
SPECIFICATIONS of LED IP44 Waterproof Microwave Induction Lamp
Power source: 100-130V/AC | Detection angle: 360° |
220-240V/AC | Detection range: 3-9m (radii.) (adjustable) |
Power frequency: 50/60Hz | Time setting: 8sec to 12min (adjustable) |
HF system: :5.8GHz CW electric wave, | Light-control: 2-2000LUX (adjustable) |
ISM band | Standby power: <0.9W |
Transmission power: <0.3mW | Luminou flux: 450lm |
Rated load: 60W Max/E27 | Net weight: about1.332kg |
Installation: indoor ceiling mount |
|
1. Please keep it away from the children.
2. Please avoid fire/high temperature/damp places for installation.
3. Please confirm when shut off the power cord access.
|
• Step1 Rotating chimney down chimney(as follow: the product should be separated into two parts as A and B)
NOTE: Chimney is fragile, please don't take too much force
|
![]() |
|
Reach is the term used to describe the radii of the more or less circular detection zone produced on the ground after mounting the sensor light at a height of 2.5m, turn the reach control fully anticlockwise to select minimum reach (approx.3m radii), and fully clockwise to select maximum reach (approx. 9m radii).
|
ATTENTION of LED IP44 Waterproof Microwave Induction Lamp: When use LED IP44 Waterproof Microwave Induction Lamp, please adjust the sensitivity to an appropriate position you need, please do not adjust the sensitivity to maximum, to avoid the product does not work normally caused by wrong motion.Because the sensitivity is too high easily detect the wrong motion by wind blowing leaves & curtains, small animals, and the wrong motion by interference of power grid & electrical equipment. All those lead the product does not work normally !
Solutions of prevent the power network pulse interference the products:
Time setting
|
The light can be set to stay ON for any period of time between approx. 8sec(turn fully anticlockwise) and a maximum of 12min(turn fully clockwise). Any movement detected before this time elapse will re-start the timer. It is recommended to select the shortest time for adjusting the detection zone and for performing the walk test.
|
Light-control setting
|
The chosen light response threshold can be infinitely from approx. 2-2000lux. Turn it fully anti-clockwise to select dusk- to-dawn operation at about 2 lux. Turn it fully clockwise to select daylight operation at about 2000lux. The knob must be turned fully clockwise when adjusting the detection zone and performing the walk test in daylight.
|
Malfunction | Cause | Remedy |
Sensor light will not switch ON | • wrong light-control setting selected | • Adjust setting |
• bulb faulty | • Change bulb | |
• mains switch OFF | • Switch ON | |
Sensor light will not switch OFF | • continuous movement in the detection zone | • check zone setting |
Sensor light switches on without any identifiable movement | • light not mounted for detecting movement reliably | • securely mount enclosure |
• movement occurred, but not identified by the sensor(movement behind wall, movement of a small object in immediate lamp vicinity etc.) | • Check zone setting | |
Sensor light does not switch ON despite movement | •rapid movements are being suppressed to minimize malfunctioning or the detection zone you have set is too small | • Check zone setting |
NOTE: the high-frequency output of this sensor is <0.3mW- that is just one 3300 of the transmission power of a mobile phone or the output of a microwave oven.
|
![]() |
The detection distance may multiply for the reflection on microwave electromagnetic field by the metal or glass materials. Thus, lower the sensitivity to reach the appropriate detection distance. Never turn the SENS knob to the maximum value to avoid error detection. Also the surrounding environment will lead to error action, e.g. the automobiles passing by or the wandering objects caused by the wind. Products should be installed more than 4 meters one from the other, otherwise the interference among them will cause error action.
The proper use of trimming potentiometer: the trimming potentiometer is used to adjust the time that sensor light turn on when detects somebody movement and turn off automatically.