HF Microwave Sensor is widely applied in the passageway, washroom, elevator, household or other public areas for security protection or energy saving. It applies for several technical patents and is the perfect choice for your intelligent living.
Specifications
Power source: 100-240VAC Power frequency: 50/60Hz Transmission power: <0.3mW Rated load: 1200W,Max,tungsten(cosφ=1)(220-240VAC) 300W,Max,fluorescent(cosφ=0.5)(220-240VAC) 600W,Max,tungsten(cosφ=1)(100-130VAC) 150W,Max,fluorescent(cosφ=0.5)(100-130VAC) Working temperature: -15°C~+70°C |
Protection level: IP20,Class II Installation sit: indoors, ceiling mounting HF system: 5.8GHz CW electric wave,ISM band Detection angle: 360°(Ceiling installation) Detection range: 1-8m (radii.) (adjustable)(Ceiling installation) Time setting: 8sec-12min, (adjustable) Light-control: 10-1000LUX, (adjustable) Power consumption: approx.0.5W |
![]() |
(1)Light-control setting It can be defined in the range of 10~1000 LUX. To turn the knob fully anti-clockwise is about 10 lux,fully clockwise is about 1000 lux.When adjusting the detection zone and performing the walk test in daylight,you should turn the knob fully clockwise. |
![]() |
(2)Time setting It can be defined from 8 seconds(turn fully anti-clockwise) to 12minutes(turn fully clockwise). Any movement detected before this time elapses will re-start the timer. It is recommended to select the shortest time for adjusting the detection range and for performing the walk test.
NOTE:When the light be auto off,it will take 1 second before the sensor is ready to detect another movement,that is,only signal detected 1 seconds later can the light be auto-on. |
![]() |
(3)Detection range setting(sensitivity) Detection range is the term used to escribe the radii of the roughly circle casting on the ground when installed at the height of 2.5 m. To turn the knob fully anti-clockwise is the minimum range, fully clockwise is the maximum. |
Fault | Failure cause | Solution |
The load fails to work. | Light-illumination is set incorrectly. | Adjust the setting of the load. |
The load is broken. | Change the load. | |
The power is off. | Turn the power on. | |
The load works all the time. | There is a continuous signal in the region of the detection. | Check the settings of the detection area. |
The load works when there is no motion signal detected. | The lamp isn't installed well so that sensor fails to detect reliable signals. | Re-adjust the installation place. |
Moving signal is detected by the sensor (movement behind the wall, the movement of small objects, etc.) | Check the settings of the detection area. | |
The load fails to work when there is motion signal detected. | The motion speed is too fast or the defined detection area is too small. | Check the settings of the detection area. |