PDLUX PD-V21 24.125GHz Millimeter Wave Radar Sensor is a K-Band Bi-Static Doppler transceiver modlue .It’s built-in Resonator Oscillator (CRO).This module,V21 adopts flat Plane Antenna, suitable for wall mounting. It can improve its front signal receiving ability and reduce its flank blind area. Its performance is better than the sensors in the market.
PDLUX PD-V21 24.125GHz Millimeter Wave Radar Sensor
![]() |
Application of PDLUX PD-V21 24.125GHz Millimeter Wave Radar Sensor ● Intelligent switch ● Wall-hung switch ● Intruder detect PDLUX PD-V21 24.125GHz Millimeter Wave Radar Sensor is a K-Band Bi-Static Doppler transceiver modlue .It’s built-in Resonator Oscillator (CRO).This module,V21 adopts flat Plane Antenna, suitable for wall mounting. It can improve its front signal receiving ability and reduce its flank blind area. Its performance is better than the sensors in the market. This module is ideally suiable for occupancy sensor in automatic lighting switches.It can also be used for ceiling mount intruder detectors. According with EN 300440-V2.1.1、EN 62479:2010 RED directive - 2014/53/EU According with FCC Part 15.249 According with EN 62321,ROHS directive - 2011/65/EU According with REACH directive - 1907/2006/EC |
Parameter |
Notes |
Min |
Typ |
Max |
Units |
Supply Voltage |
Vcc |
3.0 |
5.0 |
5.25 |
V |
Current Consumption |
Icc |
20 |
35 |
38 |
mA |
Operation Mode |
Powered by PWM, it can control the working current at 3-15mA |
||||
Pulse Width |
Tpulse |
10 |
μs |
||
Operating Temperature |
Top |
-30~+85+100(Max.) |
℃ |
||
Storage Temperature |
Tstg |
-10 |
+60 |
℃ |
|
Stable Time |
|
<5 |
μSec |
||
Frequency Setting |
f |
24.000 |
24.125 |
24.250 |
GHz |
Radiated Power (EIRP) |
Pout |
<2.0 |
<2.5 |
<3.0 |
mW |
Storage Ambient Humidity |
45%~65% |
RH |
WARNING: The actual detection range is related to the signal amplification gain of the circuit, the overall layout of the PCBA and the threshold of the MCU.
Note1: The radiated emissions is designed to meet FCC rules.
Note2: The Received Signal Strength(RSS) is measured at the total 1 Ways path loss of 70dB.
Note3: The noise voltages are measured from 10Hz to 100Hz at the Output port, inside an Anechoic chamber.
Note4: Pulse operation